Gas turbine flowmeter
]
Product Name:
Gas turbine flowmeter
Product Model:
CY
Manufacturer:
COMPLEX
file:
No Related Documents
Product Description
Measuring Machine features wide range of powerful, low power consumption, superior performance and accuracy of better than ± 1.5% for demanding high precision, the temperature below 80 degrees below t
Gas turbine flowmeter
Measuring Machine features wide range of powerful, low power consumption, superior performance and accuracy of better than ± 1.5% for demanding high precision, the temperature below 80 degrees below the gas measurement conditions with live show type, output type, on-site display + Output Optional
CY series gas turbine flow meter instrument, drawing, Guonei Wai Liu Liang advanced Jishu optimized design, synthesis gas mechanics, fluid mechanics, electromagnetism theories of a self-developed set of temperature, pressure, flow sensors and intelligent flow totalizer in whole new generation of high accuracy, high reliability, precise measurement of the gas meter, with excellent measurement performance of low pressure and high pressure, multi-signal output mode and the low sensitivity of fluid disturbance is widely used in natural gas, coal gas, liquefied gas , light hydrocarbon gas such as gas measurement.
The product was ex-proof national quality inspection department An GB3836.2000 "Electrical equipment for explosive gas atmospheres
Part 1: General requirements", GB3836.2-2000 "Electrical equipment for explosive gas atmospheres
Part 2: Flameproof" d "" and GB3836.4-2000 "Electrical apparatus for explosive gas atmospheres
Part 3: Intrinsic safety" i "" standard test pass mark for explosion-proof Exd Ⅱ BT6 (flameproof), Ex ia Ⅱ CT6 (the safety type). Applies to contain Ⅱ A, Ⅱ B, Ⅱ C Class T1 ~ T6 temperature class of explosive gas mixtures of 0 (only the safe type) 1,2 dangerous places District.
Model specifications | Nominal Path (mm) | Flow Range (m3/h) | Starting flow (m3/h) | Working pressure (MPa) | Installation Type |
CY100-25 | 25 (1") | 0.7-7 1.5-15 3-40
| 0.6 1 2 | 4.0 | Flange (optional thread |
CY100-40 | 40 (1.5") | 4-40 8-80 | 2.5 3 | 4.0 | Flange (optional thread |
CY100-50 | 50 (2") | 10-100 15-150 | 3.5 4 | 4.0 | Flange |
CY100-80 | 80 (3") | 15-300 | 4 | 1.6 | Flange |
CY100-100 | 100(4") | 20-400
| 5 | 1.6 | Flange |
CY100-150 | 150(6") | 50-1000 | 8 | 1.6 | Flange |
CY100-200 | 200(8") | 100-2000
| 20 | 1.6 | Flange |
CY100-250 | 250(10") | 150-3000 | 30 | 1.6 | |
CY100-300 | 300(12") | 200-4000 | 40 | 1.6 | Flange |
Accuracy class: 1.0 (optional); 1.5 (standard)
Conditions of Use:
* Ambient temperature: -30 ℃ ~ +60 ℃;
* Atmospheric pressure: 86KPa ~ 106KPa;
* Medium temperature: -30 ℃ ~ +80 ℃;
* Relative humidity: 5% ~ 95%
Range: (special range can be customized)
Model | output mode | Power Supply |
CY100 | Voltage pulse low ≤ 1V, high ≥ 5V, 3-wire | DC12V-24V |
CY100-A | Current output: 4 ~ 20mADC, two-wire | DC24V |
CY100-B | Correction with more precision, while the instantaneous flow and total flow display double liquid crystal display, as follows: Q XXXX 4 instantaneous flow (m3 / h) XXXXXXXX 8 total flow (m3) Note: The total flow count from the beginning 00.000000, automatic expansion of display precision, the largest recorded to 999,999.99. Total flow value can be cleared, instrument factor, power-down years of accumulated flow value is not lost. | 3.2V10AH lithium battery or DC24V |
CY100-C | In the CY100-B (on-site display type) based on the installation of 4-20mADC current output | DC24V |
CY100-D | In CY100-B (on-site display type) installed temperature and pressure sensors, flow to different conditions and automatically compensate correction operation. Can also check the temperature, pressure, battery charge and other values. Output high-frequency, low voltage pulse signal, and 4-20mADC two-wire current signal. | 3.2V10AH lithium battery or DC24V |