COMPLEX (BEIJING) TECHNOLOGY CO,.LTD
Product Material
Home >>> Product Class >>> Building Automation System >>> Protocol converter
易展国际 >>> 展馆展区 >>> BACnet to Modbus converter
[

BACnet to Modbus converter

]
sendmsg
Product Name: BACnet to Modbus converter
Product Model: GATEM
Manufacturer: COMPLEX
file:No Related Documents


Product Description

GATEM network controller is a different bus architecture for intelligent gateway and protocol conversion equipment, from a MODBUS/RS485, MeterBUS and BACnet / IP network, bi-directional conversion. Wh

BACnet to Modbus converter

Description:
GATEM network controller is a different bus architecture for intelligent gateway and protocol conversion equipment, from a MODBUS/RS485, MeterBUS and BACnet / IP network, bi-directional conversion. While built-in secondary development of advanced programming features. Can be used in central air conditioning units, chillers, lighting control systems, Remote meter, fire alarm, elevator control systems that support MODBUS protocol or products. Converted by the network controller can be found with any of the BACnet / IP protocol system interoperability.

Product features:
1, communications port to an Ethernet port and one RS485/RS232 port. Which is set to MODBUS RS485 port to achieve an agreement, set to RS232 port to achieve MeterBUS agreement.

2, MODBUS communication rate 1200,2400,4800,9600,19200,38400,57600 optional support for RTU mode. The equipment in the MODBUS protocol, you can do master (Master), there do from the side (Slave).

3, support the BACnet protocol in the AI (analog input), AO (analog output), BI (digital input), BO (switch output), PG (program objects), File (file object), Device (device object) .

4, the controller general controller, using BABEL BASIC programming language from a MODBUS memory address to the BACnet object conversion, and support for arithmetic, logical operations, mathematical functions, logic control, to achieve a flexible number conversion.

5, support the BACnet services include: Who-is, I-am, read attributes, read multiple properties, write properties of services, create objects, delete objects, read files, write files.

6, with power to maintain function, can be permanently stored configuration parameters.

7, supports up to 900 BACnet objects.

8, including configuration, including full compliance with BACnet protocol. In addition to the configuration software provided by the company, other company's software can achieve the complete configuration of the controller.

9, users only need to fill out a simple Excel configuration file, then import the Leader BABEL debugging software, download it.

Features:
full compliance with BACnet standards
DDC's embedded software using object-oriented ideas, objects to the definition and communication services fully meet the BACnet standard, is the real BACnet device.
support BACnet / IP protocol
Direct access to BABEL floor control system of single-stage network can be directly with other vendors BACnet / IP device connectivity, data exchange without the use of the gateway, and can easily access Internet.
standard Ethernet communication
Communication speed 10M/100M adaptive, allowing communication between the controller network into the integrated wiring system, the communication speed and convenient debugging.
information is not lost
All data, configuration information and user written programs are stored in flash memory to ensure the power-down without losing.
support independent operation
All the functions can be completed independently, not dependent on any device on the network.

The safety instructions
 Do not demolish GATEM network controller structure and the internal circuit board, have questions, please contact us.

GATEM network controller installation
GATEM network controller can be directly installed on the wall, recommend special equipment installed in the box.
GATEM network controller can not be directly installed in the strong electric control box and power distribution box, GATEM network controller, the installation should ensure that the work environment, meet the technical parameters of temperature and humidity requirements, taking away from strong electromagnetic environment For example: motor, high voltage, etc..

Euipment grounding
Power zero line (negative) should be good then the earth, grounding can be used connected directly to earth and the earth connected by capacitive coupling. Way of grounding capacitive coupling both the MGBT-10 network controller's own electrical safety and anti-jamming capability, GATEM network controller of special equipment box COMPLEX series equipment is used in capacitive coupling box grounded way.

Clean
GATEM network controller with semi-enclosed metal case, looks clean you can use a slightly damp cloth to wipe, but never directly to water contact GATEM network controller. GATEM network controller needs internal cleaning, if dusty, use a hair dryer.

1
MS/TP bus repeater
110044REP
MSTP-REP
MSTP-REP MS / TP bus extension, support the four MS / TP bus expansion 2 BACnet Modbus Converter
2
BACnet Modbus Converter
11004401M
GATEB1-M
GATEB1-M Modbus 485 interface to convert the BACnet MS / TP bus connection 100BV, 100AV value
3
BACnet Modbus Converter
11004402M
GATEB2-M
GATEB2-M Modbus 485 interface to convert the BACnet Ethernet connection 1000BV, 1000AV value
4
BACnet Modbus Converter
110044B11
GATEM-B11
GATEM-B11 BACnet MS / TP bus connection into Modbus 485 interfaces; 100BV, 100AV value
5
BACnet Modbus Converter
110044B12
GATEM-B12
BACnet MS / TP bus connection into Modbus 485 interfaces; 1000BV, 1000AV value
6
BACnet Modbus Converter
110044IP1
GATEM-BIP1
BACnet IP connection is converted to Modbus 485 interfaces; 100BV, 100AV value
7
BACnet Modbus Converter
110044IP2
GATEM-BIP2
BACnet IP connection is converted to Modbus 485 interfaces; 1000BV, 1000AV value
8
BACnet Modbus Converter
1100440ME
GATEB-ME
METER BUS

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报


BACnet to Modbus converter

More Products
Product Search
Contact Us
Browse by Category